2V0-41.24 exam dumps

2V0-41.24 practice question 251 of 462

VMware Certified Professional - Network Virtualization 2024. Associate level, VMware. Free question with the correct answer and a full explanation.

2V0-41.24 Question 251

Select 2

An organization is designing a VMware NSX-T Data Center environment to provide disaster recovery capabilities. They want to deploy a stretched topology for Tier-0 and Tier-1 gateways to ensure service continuity during a site failure. Which of the following are supported configurations for such a deployment?

  1. A

    Tier-0 in active-active mode with Tier-1 in active-standby mode

  2. B

    Tier-0 in active-standby mode with Tier-1 in active-standby mode

  3. C

    Tier-0 in active-active mode with Tier-1 in active-active mode

  4. D

    Tier-0 in active-standby mode with Tier-1 in active-active mode

  5. E

    Tier-0 in active-active mode with Tier-1 in no HA mode

Show answer and explanation

Correct answers: A, B

Explanation

In a VMware NSX-T stretched topology, the supported configurations must ensure redundancy and service continuity across sites. Tier-0 gateways can be deployed in either active-active or active-standby mode, but the Tier-1 gateway must complement the Tier-0 configuration to avoid inconsistencies. Tier-1 in active-standby mode is required when Tier-0 is in active-active mode, while both Tier-0 and Tier-1 can be in active-standby mode in a disaster recovery scenario.

  • A. Correct.

    Correct: Tier-0 in active-active mode with Tier-1 in active-standby mode is a supported configuration for a stretched topology. This ensures that Tier-1 services have a primary location while still being resilient to failures.

  • B. Correct.

    Correct: Tier-0 in active-standby mode with Tier-1 in active-standby mode is a supported configuration for a stretched topology. This setup provides redundancy and is commonly used in disaster recovery scenarios.

  • C. Incorrect.

    Incorrect: Tier-0 in active-active mode with Tier-1 in active-active mode is not a supported configuration for a stretched topology, as it may lead to service inconsistencies across sites.

  • D. Incorrect.

    Incorrect: Tier-0 in active-standby mode with Tier-1 in active-active mode is not a supported configuration because Tier-1 in active-active mode conflicts with the HA requirements for stretched topologies.

  • E. Incorrect.

    Incorrect: Tier-0 in active-active mode with Tier-1 in no HA mode is not supported, as no HA mode does not align with the requirements for stretched topologies.

Timed practice exam

Take a 2V0-41.24 practice test under exam conditions

55 questions in 135 minutes, drawn from this bank, with a score report and a per-question review when you finish.

Start timed exam