2V0-41.24 exam dumps

2V0-41.24 practice question 274 of 462

VMware Certified Professional - Network Virtualization 2024. Associate level, VMware. Free question with the correct answer and a full explanation.

2V0-41.24 Question 274

Select 2

An organization is setting up a new NSX-T Data Center environment. The network administrator needs to create transport zones to support workloads with different requirements. One set of workloads requires VLAN-backed segments for bare-metal servers, while another set requires overlay-backed segments for virtual machines. The administrator also wants to ensure that the management plane can communicate with both types of workloads. What transport zones should the administrator create to meet these requirements?

  1. A

    A VLAN transport zone for bare-metal workloads and an overlay transport zone for virtual machines.

  2. B

    An overlay transport zone for both bare-metal and virtual machine workloads.

  3. C

    A VLAN transport zone for bare-metal workloads and an overlay transport zone for virtual machines, with a separate VLAN transport zone for management traffic.

  4. D

    A single VLAN transport zone for all workloads and management traffic.

Show answer and explanation

Correct answers: A, C

Explanation

To meet the requirements of the scenario, the administrator must create both a VLAN transport zone for bare-metal workloads and an overlay transport zone for virtual machines. Additionally, a separate VLAN transport zone for management traffic ensures proper communication and traffic isolation. This approach adheres to best practices for transport zone creation and workload segmentation in NSX-T.

  • A. Correct.

    Correct: VLAN transport zones are used for VLAN-backed segments, which are typically required for bare-metal servers. Overlay transport zones are used for overlay-backed segments, which are suitable for virtual machines.

  • B. Incorrect.

    Incorrect: Overlay transport zones cannot support VLAN-backed segments, making this option unsuitable for bare-metal servers.

  • C. Correct.

    Correct: This configuration ensures that bare-metal workloads, virtual machines, and management traffic are properly segregated and supported using appropriate transport zones.

  • D. Incorrect.

    Incorrect: A single VLAN transport zone does not support overlay-backed segments, which are required for virtual machines.

Timed practice exam

Take a 2V0-41.24 practice test under exam conditions

55 questions in 135 minutes, drawn from this bank, with a score report and a per-question review when you finish.

Start timed exam